Two grab bars should be located in each accessible toilet stall.
One grab bar should be located behind the toilet
The second grab bar should be located on the side wall closest to the toilet fixture.
The side grab bars should be of a “cranked” design or a horizontal and vertical grab bar.
Dimensions of side grab bar
Length of horizontal grab bar: 300mm minimum
Length of vertical grab bar: 300mm minimum
Height of grab bar: 800mm from floor
Gap between WC – 150mm minimum
Dimensions of rear grab bar
Width of grab bar: 600mm minimum
Gap between WC – 150mm minimum
Height of grab bar: 800mm from floor
Urinal Grab Bars
Full length urinals are preferred for all urinals. The bottom lip should be at maximum height of 425mm from floor.
Urinals minimum 350mm deep
At least one accessible urinal should be provided wherever urinals are located
For accessible urinals, a grab bar should be provided on both sides of the urinal mounted vertically with the centreline at 1000mm high. It should be between 380- 450mm from centreline.
Where privacy screens are provided between urinals, there should be clearance of 900mm.